Protection and Automation
Molded Case Circuit Breaker (MCCB):
Function: Protection and control of electrical machinaries against overloads, short-circuits and ground fault protection (Optional).
Application : The moulded-case circuit-breakers are used in industrial and civil low voltage plants with currents from 16 to 1600A. They are used in D.C. & A.C. switchgear, for motor protection, generators, capacitors etc.
Breaking Capacity, 16 kA
Origin : Italy
Breaking Capacity, 25 kA
Origin : Italy
Breaking Capacity, 36 kA
Origin : Italy
Breaking Capacity, 50 kA
Origin : Italy
Breaking Capacity, 65 kA
Origin : Italy
MCCB ACCESSORIES
Application : The moulded-case circuit-breakers are used in industrial and civil low voltage plants with currents from 16 to 1600A. They are used in D.C. & A.C. switchgear, for motor protection, generators, capacitors etc.
Breaking Capacity, 16 kA
| Rated Current | Model No. | Number of Pole |
| 16A | Tmax T1B 160 FF R16 | TP |
| 25A | Tmax T1B 160 FF R25 | TP |
| 32A | Tmax T1B 160 FF R32 | TP |
| 40A | Tmax T1B 160 FF R40 | TP |
| 50A | Tmax T1B 160 FF R50 | TP |
| 63A | Tmax T1B 160 FF R63 | TP |
| 80A | Tmax T1B 160 FF R80 | TP |
| 100A | Tmax T1B 160 FF R100 | TP |
Breaking Capacity, 25 kA
| Rated Current | Model No. | Number of Pole |
| 16A | Tmax T1B 160 FF R16 | TP |
| 25A | Tmax T1B 160 FF R25 | TP |
| 32A | Tmax T1B 160 FF R32 | TP |
| 40A | Tmax T1B 160 FF R40 | TP |
| 50A | Tmax T1B 160 FF R50 | TP |
| 63A | Tmax T1B 160 FF R63 | TP |
| 80A | Tmax T1B 160 FF R80 | TP |
| 100A | Tmax T1B 160 FF R100 | TP |
| 125A | Tmax T1B 160 FF R125 | TP |
| 160A | Tmax T1B 160 FF R160 | TP |
Breaking Capacity, 36 kA
| Rated Current | Model No | Number of Pole |
| 200A | Tmax T3N 250 FF R200 | TP |
| 250A | Tmax T3N 250 FF R250 | TP |
| 320A | Tmax T5N 400 FF R320 | TP |
| 400A | Tmax T5N 400 FF R400 | TP |
| 500A | Tmax T5N 630 FF R500 | TP |
| 630A | Tmax T6N 630 FF R630 | TP |
Breaking Capacity, 50 kA
| Rated Current | Model No. | Number of Pole |
| 800A | Tmax T6S 800 FF R800 | TP |
| 1000A | Tmax T7S 1600 FF R1000 | TP |
| 1250A | Tmax T7S 1600 FF R1250 | TP |
Breaking Capacity, 65 kA
| Rated Current | Model No. | Number of Pole |
| 1600A | Tmax T7H 1600 FF R1600 | TP |
MCCB ACCESSORIES
| Sl No. | DESCRIPTION | SUPPORTED MCCB |
| 1 | Shunt Opening Release | T1 - T2 - T3 |
| 2 | Shunt Opening Release | T4- T5- T6 |
| 3 | Shunt Opening Release | T7 |
| 4 | Under Voltage Release | T1 - T2 - T3 |
| 5 | Under Voltage Release | T4- T5- T6 |
| 6 | Under Voltage Release | T7 |
| 7 | Auxiliary Contacts | T1 - T2 - T3 |
| 8 | Auxiliary Contacts | T4- T5- T6 |
| 9 | Auxiliary Contacts | T7 |